Residential Equipment: Range and Dryer Circuits (250.140), Cord-Connected Kitchen Appliances (422.16), Appliance Disconnects (422.31–422.35), Ceiling Fans (422.18/314.27), Room Air Conditioners (440 Part VII), Hydromassage Tubs (680 Part VII) and HVAC Service Receptacles (210.63)
The Residential Wireman form gives 12 of 80 items to Equipment & Devices, and they are the household kind: the range and dryer circuit, the dishwasher and disposer cords, the ceiling fan box, the window air conditioner, the whirlpool tub, and the receptacle the HVAC tech needs. Lessons 06-03 and 06-04 covered Articles 422/424/440 generally; this lesson collects the dwelling-specific rules and their numbers. Written from the 2026 text.
NFPA 70 National Electrical Code, 2026 edition · Reviewed 2026-09-19
The Residential Wireman form gives 12 of 80 items to Equipment & Devices, and they are the household kind: the range and dryer circuit, the dishwasher and disposer cords, the ceiling fan box, the window air conditioner, the whirlpool tub, and the receptacle the HVAC tech needs. Lessons 06-03 and 06-04 covered Articles 422/424/440 generally; this lesson collects the dwelling-specific rules and their numbers. Written from the 2026 text.
1. Range, oven, cooktop and dryer frames — 250.140
- (A) New circuits: the branch circuit includes an equipment grounding conductor and the frame is connected to it per 250.134/250.138 (4-wire cord and NEMA 14-30/14-50 receptacle).
- (B) Existing branch circuits only (no EGC in the circuit): the frame may be connected to the grounded (neutral) conductor where all of the following are met: (1) the supply is 120/240 V single-phase 3-wire or 208Y/120 V from a 3-phase 4-wire wye; (2) the grounded conductor is not smaller than 10 AWG copper or 8 AWG aluminum/CCA; (3) the receptacle grounding contacts are bonded to the equipment; and (4) the grounded conductor is insulated, or is the uninsulated conductor of Type SE cable in a branch circuit that originates at the service equipment (or SE cable from elsewhere with the grounded conductor insulated or field-covered within the enclosure).
- 250.142(B) Exception 1 is the matching permission for these existing frames; everything else on the load side of the service disconnect is grounded by an EGC, never the neutral.